Release Notes (X4 Build 6 - Build n)

X4 Build 6.5

Feature:

  • The setting "Show external files" is now taken into account for all file explorer dialogs.
  • With the new setting "LDAP search: Follow referrals" it can be prevented, that LDAP referrals are evaluated.

X4 Build 6.2

Feature:

  • CAD Support: The option "Calculate coordinate mapping from content" is also available for DGN graphics now.

X4 Build 6.1

New:

  • IF FireWin: New interface module to couple to Delta Fire Detection and Alarm Systems of Eltek Fire & Safety by Honeywell via a FireWin OPC server.

Feature:

  • IF ASIP: The license model has been extended.
  • IF AsCom: The last locations related to an alarm are available in the text macros now.
  • IF Dorma: A new RemoteExe file has been added whose path can be configured in the interface settings.
  • IF FS20: The event type for configuration faults is configurable now via the INI file.
  • IF ICAD: Events are transmitted to I-CAD including in addition the HRId now.
  • IF ICARDS: The following features have been implemented:
    - The upgrade to API 1.3 has been made.
    - The automated data supply has been extended.
    - A comprehensive integration of the data types "Anpr" and "Automation" has been done.
  • IF IGISLoop: The direct TCP/IP connection without OEMInterface is possible now.
  • IF Kaba: The lock of individual datapoints is possible now.
  • IF NSC: The command "Revision on" has been added.
  • IF SHIP: The support of protocol version 1.29a has been added including new data types (locker, hotel room, hotel suite) and imporved state evaluation.
  • IF SiPass: The support of SiPass version 2.75.14 has been added.

X4 Build 6  -  2019-05-17  Major Release

New:

  • The Hungarian language file has been added.
  • IF DallmeierAPI: New interface module based on DallmeierAPI to couple to the Dallmeier Video Management System.
  • IF Digifort: New interface module to couple to the Digifort IP Video Management System.
  • IF EBLnet: New interface module to couple to the Panasonic EBL 128/512 series fire panels via EBLnet.
  • IF LatitudeVMS: New interface module to couple to the FLIR Latitude video management system.
  • IF LightSYS: New interface module to copule to the RISCO Group ProSYS/LightSYS intruder alarm system.
  • IF OnGuard2: New interface module to couple to Lenel® OnGuard® 7.4 OpenAccess (Access control part) and Lenel® OnGuard® 7.4 OpenVideo Streaming API RTSP Connection (Video part).
  • IF SIPClient: New interface module to couple to a SIP server.

Feature:

  • For contact data in the text editor a minimum width can be defined, thus the data can be structured more easily.
  • The command "Add attachment" can be used now in global scripts as well.
  • For unaccepted events in the eventlist it can be specified in the settings, whether the text or the background should flash and which color should be used for the flashing.
  • "Delete everything" is not selected by default anymore for the restore process.
  • The text macros 1-5 can be used individually again for CSV export and import.
  • PTZ and presets are supported in the archive now, if the interface supports this feature as well.
  • The command "Print documents" supports pdf files now.
  • A global script for user change has been added.
  • CAD: Additional object properties (Animation state, visibility as well as options "Full Redraw", "Adjust position dynamically" and "Suppress overlays".) for automatic linking can be adopted automatically from DWG and DGN files.
  • Sensors that are set to revision via a control operation for the sensor group, are taken into account in the event context.
  • The Dutch language file has been revised and updated.
  • The dialogs for graphic parameters are resizable now.
  • Data packages and backups created with a newer version cannot be loaded any more.
  • File browser dialogs for parameters have been added for some actions.
  • Licence problems of individual workstations are logged in the system protocol now.
  • When executing an SQL export, the tags of events can be exported.
  • Update Manager: The handling of updates as well as the verification of the program installation has been revised.
    - An inventory file which describes the installation is maintained when (un-)installing software packages.
    - Changes to the installation can only be done by using the Update Manager or Installer. Files that have not been installed through a package are not part of the installation and therefore will not be replicated in the network.
    - Should parts of the program installation deviate from the state which is described in the inventory, the affected modules will be repaired automatically during program startup.
    - Modules can now be uninstalled using the Update Manager.
    - The ablility to generate recovery packages is no longer required and has been removed.
  • Customizer: The Hungarian language file has been added.
  • DemoPanel: The Hungarian language file has been added.
  • KeyManager: The Hungarian language file has been added.
  • Localizer: The Hungarian language file has been added.
  • ServicePanel: The Hungarian language file has been added.
  • CAD Support: A new CAD library version (ODA Platform 2019 Update 2) is used now.
  • VideoManager: All available overlays may be displayed in the video image now via the video interface instead of WinGuard.
  • IF ASIP: The Hungarian language file has been added.
  • IF ASIP: Via the device datapoint it can be selected now which datapoint categories and states should be displayed at a portable device.
  • IF Email: The Hungarian language file has been added.
  • IF FacilityManager: The Hungarian language file has been added.
  • IF Fax: The Hungarian language file has been added.
  • IF SIP: Instant messages and calls can generate events now.
  • IF SIP: The Hungarian language file has been added.
  • IF Virtual: The Hungarian language file has been added.
  • IF (All): The RemoteExe path can contain system variables now.
  • IF AEOS: The following features have been implemented:
    - Service Discovery Events are evaluated now.
    - The evaluation of Input Labels has been improved.
    - The treatment of the virtual AEpu for areas has been improved.
  • IF Aimetis: The support for SDK 7.1 has been added.
  • IF AL5: The support of protocol version 01.13.01 has been added.
  • IF AVASYSVideo: Monitors with system numbers > 65535 are supported now.
  • IF ExacqVision: The display of videos has been optimized.
  • IF GCore: The 64 bit SDK is supported now.
  • IF GCore: The aspect ratio of camera can be freely adjusted now.
  • IF Hikvision: The support for VCA (Video Content Analytics) events has been added.
  • IF ICAD: The request Id is returned now in the response to a document request.
  • IF InotecCPS: The interface is available now for X4.
  • IF iProtectAC: The support of iProtect API version 9 has been added.
  • IF JunoNET: The Hungarian language file has been added.
  • IF OnGuard2: The application ID that has been updated by Lenel is used now to establish the connection to the OnGuard server.
  • IF Panomera: PTZ and pesets are supported in the the archive now.
  • IF PaxtonNet2: The SDK version 6.0 is supported now.
  • IF Planon: The following features have been implemented:
    - The event id is stored in the same format as in the eventlist now.
    - When an event ends, the end time is transmitted to Planon via a "CloseMeldingRequest"
  • IF Senso: The sensor type "Circuit Monitor" (CM) is supported now.
  • IF SNMP: The expected encoding of incoming texts can be adjusted now.
  • IF StanleyPAC: The following features have been implemented:
    - The SDK version 4.6.333 is supported now.
    - For areas the following new commands are available: Arm area, Disarm area, Lock area, Normal door operation for area.
    - Anti-passback violations trigger an alarm now and can be resetted with an event related command.
    - Authorized door openings can be displayed at the datapoint now.
  • IF TVS: The follwoing changes have been applied:
    - Overlays are now displayed in the video image only by the interface.
    - The unused option "Lock duration" has been removed.
  • IF TVS: The maximal buffer length can be configured in the INI file now.
  • IF Variodyn: "Device information" messages are evaluated now.